7.3. Replacing Limited Life Parts
7.3.1. Replacing Paper Feed Roller Module
(1) Turn off the scanner.
(2) Remove the current Paper Feed Module. (See 8.4.1.)
(3) Take out a new Paper Feed Module in the optional
"Roller Exchange Kit (KV-SS039)".
(4) Install the new Paper Feed Module.
With the lever of the Paper Feed Roller Module lowered, insert
both protrusions into the grooves, and then slowly raise the
lever in the direction of the arrow until it clicks into place.
Note:
Make sure that the lever of the Paper Feed Roller module
is firmly locked. If the lever is not firmly locked, the lever
or the module may become damaged or may not
function correctly.