Prog ramming the 3000A Series oscilloscopes52
Copyright © 2011-2013 Pico Technology Limited. All rights reserved.ps3000abpg.en r9
2.12.26
ps3000aGetValuesTriggerTimeOffsetBulk64
PICO_STATUS ps3000aGetValuesTriggerTimeOffsetBulk64
(
short handle,
__int64 * times,
PS3000A_TIME_UNITS * timeUnits,
unsigned short fromSegmentIndex,
unsigned short toSegmentIndex
)
This function retrieves the 64-bit time offsets for waveforms captured in rapid block
mode.
A 32-bit version of this function, ps3000aGetValuesTriggerTimeOffsetBulk, is available
for use with programming languages that do not support 64-bit integers.
Applicability
Rapid block mode
Arguments
handle, the handle of the device
* times, an array of integers. On exit, this will hold the time offset
for each requested segment index. times[0] will hold the time
offset for fromSegmentIndex, and the last times index will hold
the time offset for toSegmentIndex. The array must be long enough
to hold the number of times requested.
* timeUnits, an array of integers long enough to hold the number
of requested times. timeUnits[0] will contain the time unit for
fromSegmentIndex, and the last element will contain the
toSegmentIndex. Refer to ps3000aGetTriggerTimeOffset64 for
specific figures.
fromSegmentIndex, the first segment for which the time offset is
required. The results for this segment will be placed in times[0] and
timeUnits[0].
toSegmentIndex, the last segment for which the time offset is
required. The results for this segment will be placed in the last
elements of the times and timeUnits arrays. If
toSegmentIndex is less than fromSegmentIndex then the driver
will wrap around from the last segment to the first.
Returns
PICO_OK
PICO_POWER_SUPPLY_CONNECTED
PICO_POWER_SUPPLY_NOT_CONNECTED
PICO_INVALID_HANDLE
PICO_NOT_USED_IN_THIS_CAPTURE_MODE
PICO_NOT_RESPONDING
PICO_NULL_PARAMETER
PICO_DEVICE_SAMPLING
PICO_SEGMENT_OUT_OF_RANGE
PICO_NO_SAMPLES_AVAILABLE
PICO_DRIVER_FUNCTION

Table of Contents

Other manuals for PICO PicoScope 3204A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PICO PicoScope 3204A and is the answer not in the manual?

PICO PicoScope 3204A Specifications

General IconGeneral
BrandPICO
ModelPicoScope 3204A
CategoryTest Equipment
LanguageEnglish

Related product manuals