PicoScope 3000A Series Prog rammer's Guide 55
Copyright © 2011-2013 Pico Technology Limited. All rights reserved. ps3000abpg.en r9
2.12.29
ps3000aMaximumValue
PICO_STATUS ps3000aMaximumValue
(
short handle,
short * value
)
This function returns the maximum ADC count returned by calls to get values.
Applicability
All modes
Arguments
handle, the handle of the required device
* value, pointer to a short, (output) set to the maximum ADC
value.
Returns
PICO_OK
PICO_USER_CALLBACK
PICO_INVALID_HANDLE
PICO_TOO_MANY_SEGMENTS
PICO_MEMORY
PICO_DRIVER_FUNCTION