PSEN cs3.1a/b
Operating Manual PSEN cs3.1a/b
1003295-EN-08
| 21
Connection to Pilz evaluation devices
The safety switch PSEN cs3.1a/b can be connected to Pilz evaluation devices, for example.
Suitable Pilz evaluation devices are, for example:
} PNOZelog for safety gate monitoring
} PNOZpower for safety gate monitoring
} PNOZsigma for safety gate monitoring
} PNOZ X for safety gate monitoring
} PNOZmulti for safety gate monitoring
Configure the safety switch in the PNOZmulti Configurator with switch type 3.
} PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_SafetyGate
The correct connection to the respective evaluation device is described in the operating
manual for the evaluation device. Make sure that the connection is made in accordance
with the specifications in the operating manual for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex-
ample:
} PNOZ s3 and
} PNOZmulti
A1
A2
S12
S22
A1
A2
Y32
Y1
S11
S21
12
22
1
2
3
4
5
6
7
8
PNOZ s3 PSENcode
0 V
24 V
A1
A2
S12
S22
A1
A2
Y32
Y1
S11
S21
12
22
1
2
3
4
5
6
7
8
RxTx
PNOZ s3 PSENcode
0 V
24 V
Fieldbus module
Without SDD With SDD