Project configuration
Operating Manual PSEN sc M 3.0/5.5 08-17
1005387-EN-05
| 60
Muting in one direction
Fig.: Distances between muting sensors - 2 muting sensors
Legend
[1] Safety laser scanner
A1 First muting sensor on the input side, connected to Muting 11
B1 Second muting sensor on the input side, connected to Muting 12
L Length of the object that triggers the muting state as it passes the muting
sensors
V Speed at which the object is moving
D
A-B
Distance between the muting sensors A1 and B1
D
MutingOff
Distance between muting sensor A1 and the position from which the muting
function is turned off again
6.13.4 Dynamic muting
When Activate muting is selected for an input, muting can be activated and deactivated
dynamically.
} Conditions for the occurrence of muting
– One of the configurable inputs/outputs is connected to a controller and receives a
high signal from there if muting is to be activated
– When configuring the inputs, Activate muting is configured for this input in
PSENscan Configurator
– the first sensor has detected conveyed material and the second sensor also detected
it max.4s afterwards
6.14 Override
The override function can be used for the three types in accordance with the timing dia-
grams:
} Single-channel pulses
} Activation is edge-triggered
} Activation is signal-triggered (only when using the 17-pin connection)