Recovery flowchart (1-1)...Changing the Vol Offset setting voltage
[From the main flowchart (1)]
VOL OFFSET_min1
Display RST MASK 09 (light blue). / [MKS S59]
Display RST MASK 10 (light purple). / [MKS S60]
Replacement of abnormal circuits or
re-replacement of the panel required
Set VOL OFFSET to the setting value 000. / [VOF 000]
No
Ye s
Set VOL OFFSET to the setting value 000. / [VOF 000]
Choose the higher value between VOL_OFFSET_min1 and
VOL_OFFSET_min2, and set it as VOL_OFFSET_min.
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 245 or less.
VOL OFFSET_min1 155?
Note: Disregard the discharge that may appear during
voltage-change setting.
∗ If RST MASK 09 (light blue) is already displayed, skip this step.
∗ This setting becomes
VOL OFFSET_min1.
Note:
Make a note of this VOL OFFSET_min1 value.
[To the Recovery flowchart (1-2)]
Gradually increase the VOL OFFSET value until disappear the
discharge (lit cell).
The VOL OFFSET value must be 245 or less.
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
VOL OFFSET_min2 155?
VOL OFFSET_min2
VOL OFFSET_min
∗ This setting becomes
VOL OFFSET_min2.
Note:
Make a note of this VOL OFFSET_min2 value.