SECTION 2
LIMITATIONS PA-28-181, ARCHER III
SECTION 2
LIMITATIONS PA-28-181, ARCHER III
REPORT: VB-1611 ISSUED: JULY 12, 1995
2-4
REPORT: VB-1611 ISSUED: JULY 12, 1995
2-4
2.9 POWER PLANT INSTRUMENT MARKINGS
(a) Tachometer
Green Arc (Normal Operating Range) 500 to 2700 RPM
Red Line (Takeoff Power) 2700 RPM
(b) Oil Temperature
Green Arc (Normal Operating Range) 100° to 245°F
Red Line (Maximum) 245°F
(c) Oil Pressure
Green Arc (Normal Operating Range) 55 PSI to 95 PSI
Yellow Arc (Caution Range) (Idle) 25 PSI to 55 PSI
Yellow Arc (Ground Warm-Up) 95 PSI to 115 PSI
Red Line (Minimum) 25 PSI
Red Line (Maximum) 115 PSI
(d) Fuel Pressure
Green Arc (Normal Operating Range) 0.5 PSI to 8 PSI
Red Line (Minimum) 0.5 PSI
Red Line (Maximum) 8 PSI
(e) Vacuum Gauge
Red Line (Minimum) 4.8 in Hg
Green Arc (Normal Operating Range) 4.8 in Hg. to 5.2 in Hg
Red Line (Maximum) 5.2 in Hg
2.11 WEIGHT LIMITS
Normal Utility
(a) Maximum Ramp (lbs.) 2558 2138
(b) Maximum Weight (lbs.) 2550 2130
(c) Maximum Baggage (lbs.) 200 0
NOTE
Refer to Section 5 (Performance) for maximum
weight as limited by performance.
2.9 POWER PLANT INSTRUMENT MARKINGS
(a) Tachometer
Green Arc (Normal Operating Range) 500 to 2700 RPM
Red Line (Takeoff Power) 2700 RPM
(b) Oil Temperature
Green Arc (Normal Operating Range) 100° to 245°F
Red Line (Maximum) 245°F
(c) Oil Pressure
Green Arc (Normal Operating Range) 55 PSI to 95 PSI
Yellow Arc (Caution Range) (Idle) 25 PSI to 55 PSI
Yellow Arc (Ground Warm-Up) 95 PSI to 115 PSI
Red Line (Minimum) 25 PSI
Red Line (Maximum) 115 PSI
(d) Fuel Pressure
Green Arc (Normal Operating Range) 0.5 PSI to 8 PSI
Red Line (Minimum) 0.5 PSI
Red Line (Maximum) 8 PSI
(e) Vacuum Gauge
Red Line (Minimum) 4.8 in Hg
Green Arc (Normal Operating Range) 4.8 in Hg. to 5.2 in Hg
Red Line (Maximum) 5.2 in Hg
2.11 WEIGHT LIMITS
Normal Utility
(a) Maximum Ramp (lbs.) 2558 2138
(b) Maximum Weight (lbs.) 2550 2130
(c) Maximum Baggage (lbs.) 200 0
NOTE
Refer to Section 5 (Performance) for maximum
weight as limited by performance.