32
6. Cable Connection Parameters
The wiring details are as shown below:
100FX Fiber Optical Cables:
Standard Fiber Type Cable Specication
100Base-FX (1310nm)
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/125μm
100Base-BX-U
(TX :1310/RX :1550nm)
100Base-BX-D
(TX :1550/RX :1310nm)
Single-mode 9/125μm
1000X Fiber Optical Cables:
Standard Fiber Type Cable Specication
1000Base-SX
(850nm)
Multi-mode 50/125μm or 62.5/125μm
1000Base-LX
(1310nm)
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/125μm
Wiring Distances:
Standard Fiber
Diameter
(micron)
Modal Bandwidth
(MHz * km)
Max. Distance
(meters)
1000Base-SX Multi-mode
62.5
62.5
50
50
100
200
400
500
220
275
500
550
1000Base-LX
Multi-mode
62.5
50
50
5
4
5
550
Single-mode 9 N/A 5000
1000Base-ZX Single-mode 9 N/A ~70,000
Note
The single-mode port (1000Base-LX port) of the IGS-624HPT, it
provides additional margin allowing 10/20/30/40/50/70/120 kilome-
ters Gigabit Ethernet to link on single mode fiber.