The PLANET IGS-801M is an Industrial 8-Port 10/100/1000T Managed Ethernet Switch designed for robust and reliable network management in industrial environments. This quick installation guide provides essential information for setting up and managing the device, emphasizing its remote management capabilities and ease of use.
The IGS-801M serves as a central point for connecting multiple Ethernet devices within an industrial network, offering both 10/100/1000T (Gigabit Ethernet) connectivity. As a "Managed Ethernet Switch," it provides advanced network management features, allowing administrators to configure, monitor, and troubleshoot the network remotely. This capability is crucial for maintaining network stability and performance in demanding industrial settings where physical access to devices might be limited or challenging. The switch supports various network protocols and management interfaces, ensuring compatibility with existing infrastructure and offering flexibility in deployment. Its industrial design signifies enhanced durability and resistance to environmental factors commonly found in industrial applications, such as extreme temperatures, vibrations, and electrical noise.
The IGS-801M is designed for straightforward installation and operation, even for users with limited networking experience. The device's remote login interface is a key feature, enabling management from a standard workstation. To facilitate this, the workstation needs to be running a compatible operating system such as Windows (7/8/10/11), macOS (10.12 or later), or Linux Kernel (2.6.18 or later), all of which support TCP/IP protocols. The workstation must also be equipped with an Ethernet Network Interface Card (NIC) for physical connection to the switch. Standard network (UTP) cables with RJ45 connectors are used for these connections, ensuring common and readily available components can be utilized.
The initial setup involves connecting the manager PC to the switch via an Ethernet cable. For web-based management, the manager PC's IP address must be configured within the same IP subnet as the switch. The default IP address for the IGS-801M is 192.168.0.100, necessitating the manager PC to be set to an address like 192.168.0.x (where x is any number between 1 and 254, excluding 100) with a default subnet mask of 255.255.255.0.
Accessing the web management interface is done through a web browser. The guide recommends using modern browsers like Google Chrome (version 98.0.xxx or above), Microsoft Edge, or Firefox for optimal compatibility. Users simply enter the default IP address (https://192.168.0.100) into the browser to reach the login screen. Upon the first login, users are prompted to enter the default username "admin" and a unique default password. This password is dynamically generated based on the device's MAC ID: "sw" followed by the last six lowercase characters of the MAC ID. For example, if the MAC ID is A8F7E0XXXXXX, the default password would be "swxxxxxx". This security measure ensures that each device has a unique initial password, enhancing security from the outset.
After successfully logging in with the default credentials, the system immediately prompts the user to change the initial password to a permanent one. This new password must adhere to specific complexity rules, typically requiring 8-32 characters, including a mix of uppercase letters, lowercase letters, numerals, and other symbols, with spaces explicitly disallowed. This step is critical for establishing robust security for the device. Once the new password is set, users can log in with "admin" and their newly created password to access the full web interface.
The web management interface is structured with a comprehensive menu on the left side, providing access to all the switch's functions and statuses. These menus are categorized into System, Switching, QoS, Security, Ring, and Maintenance. Under the System menu, users can manage general device settings, time settings, log management, SNMP management, RMON (Remote Monitoring), and remote management configurations. The Switching menu offers control over port management, link aggregation, VLANs (Virtual Local Area Networks), Spanning Tree Protocol, multicast settings, IGMP (Internet Group Management Protocol) snooping, MLD (Multicast Listener Discovery) snooping, LLDP (Link Layer Discovery Protocol), and the MAC address table. QoS (Quality of Service) settings allow for basic QoS mode configuration, bandwidth control, storm control, and Voice VLAN management, ensuring critical network traffic is prioritized. The Security menu provides features such as access security, AAA (Authentication, Authorization, and Accounting), 802.1X authentication, port security, DHCP (Dynamic Host Configuration Protocol) snooping, Dynamic ARP (Address Resolution Protocol) Inspection, IP Source Guard, DoS (Denial of Service) protection, and access control lists. For network redundancy, the Ring menu includes a Ring Wizard and ERPS (Ethernet Ring Protection Switching) configurations. Finally, the Maintenance menu offers options for switch maintenance and diagnostic tools. This structured interface allows for efficient and comprehensive management of the industrial switch.
The IGS-801M incorporates several features to aid in maintenance and ensure continuous operation. Power Input Wiring: The device's upper panel includes a DC inlet power socket with a 6-contact terminal block connector. Users can insert positive/negative DC power wires into Contacts 1 and 2 for POWER 1, or 5 and 6 for POWER 2. The wire-clamp screws must be tightened to prevent wires from loosening, ensuring a secure and reliable power connection. The terminal block supports wire gauges between 12 and 24 AWG. The power input range is flexible, supporting 12V to 48V DC, and also accommodates 24V AC (though only one power input should be used when operating with 24V AC). This flexibility in power input options makes the switch adaptable to various industrial power infrastructures.
Grounding: A critical maintenance step is proper grounding of the device. Users MUST complete grounding the device to prevent fatal damage from sudden lightning strikes or other electrical surges. The Earth Ground connection point is clearly indicated on the device's terminal block, emphasizing its importance for safety and device longevity.
Resetting to Default: In cases where configurations need to be cleared or access credentials are lost, the IGS-801M provides a hardware-based reset function. By pressing the reset button on the side panel for approximately 10 seconds, the device's IP address will revert to the default 192.168.0.100, and the user password will be reset to the factory default mode (sw + the last 6 lowercase characters of the MAC ID). It's important to note that performing a factory default reset will erase all previous configurations, returning the switch to its out-of-the-box state. After the device reboots, users can log in using the default credentials and reconfigure the switch as needed. This feature is invaluable for troubleshooting or redeploying the switch in a new network environment.
Customer Support: PLANET provides comprehensive customer support resources. Users can access online FAQs on the PLANET website to find solutions to common issues. For more specific support, a dedicated switch support team can be contacted via email. The user's manual for the IGS-801M is also available online, offering detailed information beyond the quick installation guide. These resources ensure that users have access to the necessary information and assistance for maintaining their device.
In summary, the PLANET IGS-801M is a robust and manageable industrial Ethernet switch designed for reliable performance in challenging environments. Its remote management capabilities, flexible power options, and straightforward maintenance features, including easy grounding and a factory reset option, make it a practical solution for industrial networking needs.
| Power Input | 12~48V DC, redundant power with polarity reverse protect function |
|---|---|
| Operating Temperature | -40°C to 75°C |
| Mounting | DIN rail |
| Switch Architecture | Store and Forward |
| MAC Address Table | 8K |
| Jumbo Frame | 9K bytes |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5~95%, Relative Humidity (Non-condensing) |