EasyManua.ls Logo

Planet VIP-200 - E&M Signaling Commands

Planet VIP-200
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIP Users Manual
Command Line Interface
83
7.13 E & M Signaling Commands
E&M Common Signaling Configuration Commands
The E&M common signaling configuration commands are used to define common parameters used
on all E&M interfaces, regardless of their mode of operation (Wink Start, Delay Start, or Immediate
Start).
set port port em clear_conf_detect
This command is used to set the minimum duration of on-hook response on the M-lead that is re-
quired for clear confirm to be detected.
set port port em clear_conf_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to
65535.
Default
5000
set port port em clear_conf_wait_max
This command is used to set the maximum duration to wait for an on-hook response on the M-lead
after going on-hook on the E-lead.
set port port em clear_conf_wait_max milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default
10000
set port port em clear_detect
This command is used to specify the period of time M-lead needs to be on-hook before call clearing
is declared.
set port port em clear_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 0 to 65535.
Default

Table of Contents