EasyManuals Logo

Planet XGS3-24242 User Manual

Planet XGS3-24242
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #550 background imageLoading...
Page #550 background image
56-6
Figure 56-3 The Topology of IPv6 Radius configuration
A computer connects to a switch, of which the IP address is 2004:1:2:3::2 and connected with a RADIUS
authentication server without Ethernet1/2; IP address of the server is 2004:1:2:3::3 and the authentication port
is defaulted at 1812, accounting port is defaulted at 1813.
Configure steps as below:
Switch(config)#interface vlan 1
Switch(Config-if-vlan1)#ipv6 address 2004:1:2:3::2/64
Switch(Config-if-vlan1)#exit
Switch(config)#radius-server authentication host 2004:1:2:3::3
Switch(config)#radius-server accounting host 2004:1:2:3::3
Switch(config)#radius-server key test
Switch(config)#aaa enable
Switch(config)#aaa-accounting enable
56.4 RADIUS Troubleshooting
In configuring and using RADIUS, the RADIUS may fail to authentication due to reasons such as physical
connection failure or wrong configurations. The user should ensure the following:
First make sure good condition of the RADIUS server physical connection;
Second all interface and link protocols are in the UP state (use “show interface” command)
Then ensure the RADIUS key configured on the switch is in accordance with the one configured on
RADIUS server;
Finally ensure to connect to the correct RADIUS server
If the RADIUS authentication problem remains unsolved, please use debug aaa and other debugging
command and copy the DEBUG message within 3 minutes, send the recorded message to the technical
server center of our company.

Table of Contents

Other manuals for Planet XGS3-24242

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet XGS3-24242 and is the answer not in the manual?

Planet XGS3-24242 Specifications

General IconGeneral
Switching Capacity128 Gbps
Forwarding Rate95.23 Mpps
MAC Address Table16K entries
Jumbo Frame9K bytes
Ports24 x 10/100/1000BASE-T
Throughput95.2 Mpps
Power Supply100~240V AC, 50/60Hz
Power Consumption30W (max)
Dimensions (W x D x H)440 x 44 mm
Operating Temperature0 to 50°C
Storage Temperature-40°C to 70°C
Operating Humidity5 to 95% non-condensing
Storage Humidity5 to 95% non-condensing