SETTINGS
D-7
MacR6-Z0 – USER MANUAL
End of the billing month
Typing value 1, when Report Hour is set to 6 means, that billing month ends at
every 1st day of the month at 6am.
Value 31 means that every last day of the month is the end of the billing month.
Registration
Report Hours
Sequence of additional report sending hours - only registered data. Value of
this parameter is calculated from 24-bit binary vector, where:
bit 0 - 0 hour (midnight)
bit 1 - 1 am
bit 2 - 2 am
...
bit 13 - 1 pm
bit 23 - 11pm
For reports sent at 6am, 12 pm, 4pm, 0 am:
Decimal value of the record above is "69697" to set in the parameter. Report
on 6am is the result of end of the billing day. Setting this bit to 0 or 1 does not
have any influence on sending this report.
Setting of the delay in report sending given in minutes according to report hour:
0 - no delay (data sent immediately)
10 - delay from 0 to 9 minutes
20 - delay from 10 to 19 minutes
30 - delay from 20 to 29 minutes from report hour
Clock adjustment:
0 - automatic time change according to the local time
1 - winter time only
2 - daylight saving time only