Operating Instructions MSA 2 MULTI Technical characteristics
23
6 Technical characteristics
Mains voltage and
frequency
230 V (265V÷190V) 50/60 Hz
Suggested power
generators
3.5kW
Welding technique Voltage controlled
Fusion voltage 3.6÷40V
Operating temperature - 20 °C / +50°C
Internal temperature - 20°C / +70°C
Temperature sensor
resolution
± 1°C
Fittings range Ø20mm ÷ 630mm
Fusion data input mode Bar code, manual
Capacity of internal memory 500 protocols
USB Port Type A
Protection factor IP 65
Dimensions 280x280x420 mm (max)
Weight 11,9 kg
6.1 Standards
ISO 12176-2
ISO 12176-3
ISO 13950
EN 60335 (Safety)
EN 61000-6-2/4 (EMC)