Instruction book
32 9828 0931 61
4.3 During operation
Procedure
Re
gularly check:
The display of digital controller. The pressure dewpoint will deviate from nominal if the air inlet
conditions or volume flow differ from nominal.
That condensate is discharged via condensate outlet. The amount depends on the operating
co
nditions.
4.4 Stopping
Attention
To ensure optimum operational efficiency, do not use dryer on/off switch (1)
repeatedly within a short time period.
Wait at least 5 minutes to start
the dryer again after stopping to allow pressure
equalization.
To keep the compressed air net free of condensate, start the dryer before starting the
compressor and stop the compressor before stopping the dryer.