4.5 Pressure discharge procedure
Follow below procedure to depressurize the dryer:
1. Close the ball valve (1).
2. Remove the panel (2).
3. Release the pressure in the dryer by pressing the condensate drain “TEST” pushbutton located on the steam
trap (3).
4. Switch off the machine. Turn the switch to “STOP” (4).
5. Turn on the supply automatic differential switch (5).
6. Close the panel (2).
4.6 Dismantling
Description
Before dismantling, the responsible operating department must de-commission the system and ensure that it
i
s de-pressurized.
Dismantle the product according to local legislation.