Instruction book
9828 0931 61 41
8 Technical data
8.1 Reference conditions and limitations
Reference conditions
Unit
Compressed air inlet pressure bar(e) 7
Compressed air inlet pressure psig 101.53
Compressed air inlet temperature
- 50 Hz dryers ˚C 35
- 50 Hz dryers ˚F 95
- 60 Hz dryers ˚C 38
- 60 Hz dryers ˚F 100
Ambient temperature
- 50 Hz dryers ˚C 25
- 50 Hz dryers ˚F 77
- 60 Hz dryers ˚C 38
- 60 Hz dryers ˚F 100
Pressure dewpoint
- 50 Hz dryers ˚C 3
- 50 Hz dryers ˚F 37.4
- 60 Hz dryers ˚C 4
- 60 Hz dryers ˚F 39
Limits
Unit
Maximum compressed air inlet pressure bar(e) 14
Maximum compressed air inlet pressure psig 203
Min.-max. ambient air temperature ˚C 1-46
Min.-max. ambient air temperature ˚F 39-115
Max. compressed air inlet temperature ˚C 60
Max. compressed air inlet temperature ˚F 140