PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
No Dark Slide Cycle 9. Battery contact height 9. Replace battery
(cont’d) marginal or not seated contacts.
properly.
10.Flex circuit defective. 10.Replace flex circuit
No S1 response 1. Defective S-1 button 1. Replace S1 button
or S-l slider. or S1 slider.
2. S1 slider and contact 2. Disassemble and
support block not install properly.
interfaced properly.
3. S1 switch contacts de- 3. Re-form S-1 contacts
formed (do not close). or replace contact
support block if
necessary.
4. Poor connection between 4. Check connection and
flex circuit and solenoid. correct problem.
5. S9 is closed (check with 5. Re-form S-9 contacts
meter). NOTE: In this or replace contact
failure, camera will cycle support block, if
but blades remain closed. necessary.
6. Solenoid defective 6. Replace solenoid.
(should read 2 to 3 ohms).
Continuous Cycle 1. Pack pawl override 1. See RIB #600AM 6.
(Camera ejects
film continuously) 2. Solenoid gap incorrect. 2. Adjust solenoid gap.
3. Shutter blades binding: 3. Repair or replace
blades as necessary.
a. Foreign matter on
blades.
b. Blades distorted.
c. Blades not attached
to walking beam.
4. Blade guide pin in 4. Replace shutter
shutter baseblock broken baseblock.
5. Shutter latch binding. 5. Correct cause of
binding.
6. Solenoid plunger sticky. 6. Repair/replace
solenoid.
80