POLYCOM REALPRESENCE COLLABORATION SERVER V.8.6 APPLIANCE EDITION INSTALLATION
INSTALLING THE REALPRESENCE COLLABORATION SERVER (RMX) 4000
P
OLYCOM REALPRESENCE COLLABORATION SERVER GETTING STARTED GUIDE 43
8. Turn ON the circuit breaker on each of the DC PEMs.
ADDITIONAL INFORMATION: On the RealPresence Collaboration Server (RMX)
4000, two types of circuit breakers can be installed:
• ON/OFF circuit breaker-Type A
• ON/OFF circuit breaker with locking mechanism-Type B
Connecting Cables to RealPresence Collaboration Server (RMX) 4000
Write down the serial number of the RealPresence Collaboration Server, located
on a sticker on the back of the unit. It will be needed for product registration
later in the process. Perform following steps to connect cables to the RealPres-
ence Collaboration Server (RMX) 4000.
Connect Cables to the RTM-IP 4000 Card of RealPresence Collaboration Server (RMX)
4000
• To connect cables to the RTM-IP 4000 card of RealPresence Collabora-
tion Server (RMX) 4000:
• Connect the Signaling cable to LAN 3. This port is also available for
Signaling and Management Redundancy.
• Connect the Management Network cable to LAN 2.
ADDITIONAL INFORMATION: For more information, see LAN Redundancy and
Multiple Network Services in the RealPresence Collaboration Server (RMX)
1800/2000/4000 Administrator Guide.
• Connect the Shelf Management cable to LAN 6.
ADDITIONAL INFORMATION: When an NTP Server is used for the RMX Time, the
Shelf Management cable must be connected to the shelf port.