EN| 7
EN
2.3 Technical specications
2. Description
OKU Mini 4
Air
(1)
26°C
Water
(2)
26°C
Heating power (W)
4000
Consumption (W)
748
COP (Coe. of performance)
5,35
Air
(1)
15°C
Water
(2)
26°C
Heating power (W)
3220
Consumption (W)
709
COP (Coe. of performance)
4,54
Air
(1)
35°C
Water
(2)
27°C
Cooling capacity (W)
-
Consumption (W)
-
EER (Energy Eciency Ratio)
-
Electricity supply 220-240V single-phase ~ 50Hz
Maximum power (W)
1250
Maximum current (A)
5,7
Heating temperature range
15°C ~ 40°C
Operating range
8°C ~ 43°C
Unit dimensions L × W × H (mm)
396 x 286 x 363
Unit weight (kg)
23
Sound pressure level at 10 m (dBA)
(3)
29
Hydraulic connection (mm)
PVC 32 / 38mm
Heat exchanger
PVC tank and titanium heating coil
Min. water ow rate (m³/h)
2,0
Compressor type
Rotatif
Refrigerant
R32
Waterproof IP
IPX4
Load loss (mCE)
0.8
Max. pool volume (m
3
)
(4)
≤28
Control panel
LCD screen
Mode
Heating
The technical specications of our heat pumps are provided for information purposes only. We reserve the right
to make changes without prior notice.
1
Ambient air temperature
2
Initial water temperature
3
Noise at 10 m in accordance with Directives EN ISO 3741 and EN ISO 354
4
Calculated for an in-ground private swimming pool covered with a bubble cover.