MAINTENANCE OF YOUR SURECHLOR 4000
Your Surechlor 4000 Auto Kleen has been designed to operate for extended
periods with a minimum of maintenance. The cell cleaning function is performed
automatically via the inbuilt electronic control module.
Cell Cleaning (Manual Procedure)
1. Remove Surechlor Power Pack plug from 240 volt power point.
2. Remove cell from plumbing line.
3. Turn cell upside down (ports facing upwards) and place on a level non-metallic
surface in a well ventilated area.
Warning: Rubber gloves and protective eyeware must be worn before proceeding to
the next steps!
4. Prepare an 8:1 acid cleaning solution by firstly measuring 2 litres of water into a
plastic bucket and then carefully adding 250ml of Hydrochloric Acid.
Stir thoroughly with a wooden stick.
5. Carefully pour sufficient cleaning solution into upturned cell so as to fully cover
metal electrodes.
6. Allow to stand for 10 minutes then flush out with clean water.
Do not put used acid solution into pool.
7. If electrodes still show white deposits, repeat the above steps.
Note: It is recommended that a warm
water detergent solution be used to
soak the electrodes at this point if
there is any evidence of body fats,
oils or greases.
8. Re-fit cell to plumbing line
making sure both rubber “O”
ring seals are in place.
9. Re-connect plug of Power
Pack to 240 volt power point
and switch on.
Note:
This system is fitted with a backup battery and real time clock. The time will not
require resetting.