CONNECTING THE POOL PUMP
Plug the pool pump into the pump socket at the bottom of the unit.
(see Note below about the use of large or 3 phase pumps).
Off-Peak Installations
This unit is suitable for off-peak tariff supply.
Warning: The Warranty will be void if the Power Pack is installed or operated .....
a) on, or less than 1 metre from the ground.
b) in a position where flooding from ground water could occur.
c) where the airflow is obstructed, i.e. within an unvented auxiliary enclosure.
d) with a load (pump) connected to the 240 volt pump outlet socket greater than
1.5kw (continuous).
e) from an electrical supply socket which is not rated to supply 10 amps at 240 volts
50Hz and is not adequately protected by the correct size fuse or circuit breakers.
Note: If a pump load greater than 1.5Kw or the use of a 3 phase pump is required, an
interface relay must be installed.
If double adaptors or stackable plugs are employed to operate more than one pump
directly from this Pump Outlet Socket the Warranty will be void.
Please refer to your Poolrite State Office for details.
ADDING SALT TO THE POOL
Start up procedure for marble surface pools
For new concrete pools with marble plaster (marblesheen) finishes we recommend that
the salt not be added to the pool until the excess calcium compounds in the plaster
have leached out and the pH of the water has stabilised.