SETTINGS AND CONTROLS
CHLORINE CONTROL all models
Because your Surechlor 4000 has been designed to operate over a wide range of salt
levels, water temperature, running time, etc., a Chlorine Control has been provided to
compensate for these variations.
When first starting the unit and where maximum chlorine production is needed the
output should be set to maximum.
The Chlorine Control on all Surechlor 4000 models can be set to maximum if higher
salt levels are used without the risk of damage occurring, due to the incorporation of
electronic output limiting.
To operate the filter pump only without the cell, press the menu button until “Manual
Control” appears on the display and press enter.
Press enter until “Pump” appears.
Press
or to turn the pump on or off.
OUTPUT MONITOR
This multi-function display has been provided to allow monitoring of the current
passing through the electrolytic cell to allow you to gauge the operation of the cell and
the chlorine production. This assists in determining the condition of the electrolytic cell.
The output may be adjusted with the up
or down buttons, from 10% to 100%.
A bar graph will indicate the actual output.
Each bar is equal to 10% production.
Example: 3 bars is 30%.
OPERATING INSTRUCTIONS
Using The Salt Test
Press the menu button once and press the enter button. The system will display the
message “SALT OK” or “SALT LOW”.
Using Super Chlorination
Press the menu button twice and press enter. The up button will turn on super
chlorination and the down button will turn it off. The system will run for 12 hours at
100% and display a count down timer.
Using Manual Control
Press the menu button three times and press enter. To activate the pump, press enter.
The up button will turn it on and the down button will turn it off. To turn on the
chlorinator and pump, press enter again. The up button will turn it on and the
down
button will turn it off.