_Disconnect toolfromairsupplybeforeperforminganyService
Procedure.
SYMPTOM PROBLEMS SOLUTIONS
1. Air leak near top of Loose screws. Tighten screws.
tool or in trigger area. Worn or damaged Install Overhaul Kit.
o-rings or seals.
2. Tool does nothing or Inadequate air supply. Verify adequate air supply.
operates sluggishly. Inadequate lubrication. Put 5 or 6 drops of oil into air inlet.
Worn or damaged Install Overhaul Kit.
o-rings or seals.
3. Air leak near bottom Loose screws. Tighten screws.
of tool. Worn or damaged Install Overhaul Kit.
o-rings or bumper.
4. Tool jams frequently. Incorrect fasteners. Verify approved fasteners of
correct size.
Replace w/undamaged fasteners.
Tighten screws.
Damaged fasteners.
Magazine or nose
screws moose.
Magazine is dirty. Clean magazine.
Driver is worn or damaged. Install "DRIVER" Maintenance Kit.
5. Other. Contact a Porter-Cable
Service Facility.
A complete line of accessories is available from your Porter-Cable • Delta
Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-Cable
Authorized Service Stations. Please visit our Web Site www.porter-cable.com
for a catalog or for the name of your nearest supplier.
_Since accessories, other than those offered by Porter-
Cable • Delta, have not been tested with this product, use of such
accessories could be hazardous. For safest _, only Porter-
Cable o Delta recommended accessories should be used with this
product.
13