TROUBLESHOOTING
WARNING: Disconnect tool from air supply before performing any
Service Procedure.
SYMPTOM PROBLEMS SOLUTIONS
1. Air leak near rear of Loose screws. Tighten screws.
tool or in trigger area. Worn or damaged Install Overhaul Kit.
o-rings or seals.
2. Tool does nothing or Inadequate air supply. Verify adequate air supply.
operates sluggishly. Inadequate lubrication. Put 2 or 3 drops of oil into air inlet.
Worn or damaged Install Overhaul Kit.
o-rings or seals.
Pin jammed in nose. Remove front plate and clear.
3. Air leak near bottom Loose screws. Tighten screws.
of tool. Worn or damaged Install Overhaul Kit.
o-rings or bumper.
4. Tool jams frequently. Incorrect fasteners. Verify approved fasteners of
correct size.
Pin fragment jammed in nose. Remove front plate and clear.
Fasteners loaded Verify arrow printed on fastener strip
incorrectly. points toward workpiece.
Damaged fasteners. Replace w/undamaged fasteners.
Magazine or nose Tighten screws.
screws loose.
Magazine is dirty. Clean magazine.
Driver is worn or damaged. Install Driver Maintenance Kit.
5. Other. Contact a Porter-Cable
Service Facility.
903607- 01-23-02.qxd 1/29/02 12:51 PM Page 10