5.0 Care of the Boiler
5.1 Cleaning the Outercase
1. The painted panels should be wiped with a
damp cloth and then dried completely. DO NOT
USE ABRASIVE CLEANING AGENTS.
5.2 Protection & Precautions
1. The boiler incorporates an integral frost
protection feature that will operate in both modes.
If the boiler temperature falls below 4° C, the
boiler will fire until a temperature of 15° C is
reached.
2. If a system frost thermostat has been fitted
(your installer will be able to advise you), then to
operate correctly and protect your system, the
gas and electricity must be left on and the
appliance set in the central heating mode.
3. The boiler incorporates an integral pump
protection feature which monitors the time since
the pump last operated and will operate the
pump for approximately 1 minute if it has not run
in the last 24 hours.