9
Internal battery powered with a long life, or external 6 to 24 V DC power source (0.5 amps).
Back lit LCD Display, 40 x 40mm, 128 x 128 pixels, to help with on-site setup & diagnosis
Quad-band operation
USB port for programming & firmware upgrade.
Expansion board socket for future use.
As the Metron2 is normally a battery powered device it has been designed in such a way to extend this life to a
maximum. This means during normal operation the display will be off, the sensors excitation will be off and the
GSM engine will be powered down. As required these are switched on by the processor and when finished with
they are switched off. If the unit is powered from an external source then the unit can be configured so that the
GSM engine is always on.
2.4 Specification
4 x 3 Pin 3.81mm Pitch for Sensors, 1 x 2 PIN for power
24 Months RTB. Does not cover above or incorrect
installation
Class 1 (1W) 1800/1900 MHz
3.6, or 6 to 24 V DC @ 0.5A – please ensure supply is
smooth. Check the type of Metron2 you have.
Excitation Supply (To
sensors)
3.6 v (unregulated), 5 v or 21.6 v. 31.25mA maximum
Internal or external (via SMA connector)
40 x 40mm, 128 x 128
pixels
4 x 3 Pin 3.81mm Pitch for Sensors, 1 x 2 PIN for power