If There is No Power
Make sure to unplug the unit while checking connecons or anything pertaining to the
electronic box and plug back in when tesng.
Possible Causes of No Power:
1. Power Source
2. Circuit Breaker
3. E-Box wiring
4. Control Panel
Troubleshoong
Step 1 Power Source
- Inspect the power cord and its connecon to the power source.
- Power Breezer fans can draw as much as 15 to 20 Amps on startup at Full Power. Check
the power source’s circuit breaker.
- Verify the power source with a Digital Volt Meter. Set your meter for MODE: A/C voltage ,
RANGE: 300 or higher.
- Measure the power source voltage and be sure that it matches your Breezer voltage.
a. If there is a discrepancy, correct the issue and retest.
b. If everything matches and sll No Power , go to step 2.
Step 2 The Power Breezers Circuit Breaker
- The circuit breaker, on the Power Breezer, when turned on, is lit.
- Verify the switch is in the correct posion.
a. Power from the wall goes first to the circuit breaker. If the breaker has power but
the light is not on, change the circuit breaker and retest.
b. If the breaker is on and sll No Power , go to step 3.
Step 3 VFD and the wiring of the E-Box
- Open the E-Box and compare the E-Box to the drawing 180-700-750 wiring diagram.
a. If the E-Box not wired correctly, fix the issue and re-test.
b. If the E-Box is wired correctly, connue.
c. If correct, go to step 4.
Step 4 Control Panel
- Substute the Control Panel with a known good Control Panel and test.
- If the unit is working with the substuted Control Panel then replace the Control Panel
and test.
- If the unit is sll not working: contact Customer Service by email at
customerservice@powerbreezer.com or by phone at 844-233-5673.
End of this secon