Head Is Not Rotang
Make sure to unplug the unit while checking connecons or anything pertaining to the
electronic box and plug back in when tesng.
Possible Causes of Rotaon Failure:
1. Obstrucon
2. Control Panel
3. Wiring of the E-Box
4. Rotaon Motor
Troubleshoong
Step 1 Obstrucon
- Look over your Breezer and pay aenon to the Head.
a. Is the head seated correctly on the pole? Look at the boom of the head and
verify that the pole is inserted into the head uniformly.
b. Can the head freely move side to side? Check to make sure that cables did not
get wrapped around the pole.
c. Grab the head and gently see if you can move it le to right.
d. If not, determine why and retest.
e. If it does, go to step 2.
Step 2 Control Panel
- Verify the wiring of the Control Panel in the E-Box with the 180-700-750 wiring diagram.
- Substute the Control Panel with a known good Control Panel and test.
- If the Rotaon funcon is working with the substuted Control Panel then replace the
Control Panel and test.
- If the head is not rotang, go to step 3.
Step 3 Wiring
- Verify by comparing the rest of the E-Box to the drawing 180-700-750 wiring diagram.
- If the E-Box is not wired correctly, fix the issue and re-test.
- If the E-Box is wired correctly, go to step 4.