EasyManua.ls Logo

Power Breezer Mach 4+ - Troubleshooting: Atomizer Not Misting

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Head Is Not Rotang
Make sure to unplug the unit while checking connecons or anything pertaining to the
electronic box and plug back in when tesng.
Possible Causes of Rotaon Failure:
1. Obstrucon
2. Control Panel
3. Wiring of the E-Box
4. Rotaon Motor
Troubleshoong
Step 1 Obstrucon
- Look over your Breezer and pay aenon to the Head.
a. Is the head seated correctly on the pole? Look at the boom of the head and
verify that the pole is inserted into the head uniformly.
b. Can the head freely move side to side? Check to make sure that cables did not
get wrapped around the pole.
c. Grab the head and gently see if you can move it le to right.
d. If not, determine why and retest.
e. If it does, go to step 2.
Step 2 Control Panel
- Verify the wiring of the Control Panel in the E-Box with the 180-700-750 wiring diagram.
- Substute the Control Panel with a known good Control Panel and test.
- If the Rotaon funcon is working with the substuted Control Panel then replace the
Control Panel and test.
- If the head is not rotang, go to step 3.
Step 3 Wiring
- Verify by comparing the rest of the E-Box to the drawing 180-700-750 wiring diagram.
- If the E-Box is not wired correctly, fix the issue and re-test.