EasyManua.ls Logo

Power Breezer Mach 4+ - Atomizer Not Spinning

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Atomizer Not Spinning
Make sure to unplug the unit while checking connecons or anything pertaining to the
electronic box and plug back in when tesng.
Possible Causes of Atomizer Failure:
1. Control Panel
2. Wiring of the E-Box
3. Power Supply for the Atomizer
Troubleshoong
Step 1 Control Panel
- Verify the wiring of the Control Panel.
- Substute the Control Panel with a known good Control Panel.
- If the Atomizer is working with the substuted Control Panel, test.
- If the Atomizer is sll not working, go to step 2.
Step 2 Wiring
- Open E-Box.
- Compare the E-Box to the drawing 180-700-750 wiring diagram.
If the E-Box is not wired correctly, fix the issue and re-test.
If the E-Box is wired correctly, go to step 3.
Step 3 Atomizers Power Supply
- Verify you have the correct voltage for the Atomizer on the output of the Power Supply.
a. Use a DVM to measure the DC voltage coming out of the Power Supply, it should
be 24V measured on the V+ & V- and re-check the connecons.
b. If the voltage is correct and everything else checks out, please contact Customer
Service by email at customerservice@powerbreezer.com or by phone at
844-233-5673.
End of secon