Atomizer Not Spinning
Make sure to unplug the unit while checking connecons or anything pertaining to the
electronic box and plug back in when tesng.
Possible Causes of Atomizer Failure:
1. Control Panel
2. Wiring of the E-Box
3. Power Supply for the Atomizer
Troubleshoong
Step 1 Control Panel
- Verify the wiring of the Control Panel.
- Substute the Control Panel with a known good Control Panel.
- If the Atomizer is working with the substuted Control Panel, test.
- If the Atomizer is sll not working, go to step 2.
Step 2 Wiring
- Open E-Box.
- Compare the E-Box to the drawing 180-700-750 wiring diagram.
If the E-Box is not wired correctly, fix the issue and re-test.
If the E-Box is wired correctly, go to step 3.
Step 3 Atomizer’s Power Supply
- Verify you have the correct voltage for the Atomizer on the output of the Power Supply.
a. Use a DVM to measure the DC voltage coming out of the Power Supply, it should
be 24V measured on the V+ & V- and re-check the connecons.
b. If the voltage is correct and everything else checks out, please contact Customer
Service by email at customerservice@powerbreezer.com or by phone at
844-233-5673.
End of secon