POWER ELECTRONICS
VS65 SERIES MV SOFT STARTER
TYPICAL CONFIGURATION
39
E
N
G
L
I
S
H
7. TYPICAL CONFIGURATION
7.1. Start
7.2. Stop
SCREENS
CURRENT
LIMIT
START
VOLTAGE RAMP AND CURRENT
LIMIT START
CONSTANT
ACCELERA
TION
START
(DTC)
TORQUE
PULSE
START
(LOCKED
ROTOR)
Light
Medium
Heavy
G4 1 STR DELAY=
0s
0s
0s
0s
0s
0s
2 PULS TORQ =
35-40%
35%
40%
50%
40- 45%
70 - 80 %
3 PULS TQ T =
OFF
OFF
OFF
OFF
OFF
0,2-0,5
4 INIT TORQ =
35-40%
35%
40%
50-60%
40- 45%
50 - 70 %
5 INIT TQ T =
0 s
0
0
1
1s-2s
0-10
6 ACEL TIME =
1s
4 6s
4 6s
6 8s
10s-30s
1-180
7 I LIMIT =
3.5 -4 x In
3 3.5 In
3.5 4 In
4 5 In
2,5 3 In
3,5 x In
SCREENS
DEFAULT
PARAMETERS
SPIN STOP
VOLTAGE RAMP
STOP
G5. 1 FREWEL STP =
Y
YES
NO
2 DECL TIME =
12s
-
f (load)
3 DEC MD SEL =
1*
-
1
4 HAMR FACT =
75%
-
-
5 MINI TORQ=
1%
-
-

Other manuals for Power Electronics VS65 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Power Electronics VS65 Series and is the answer not in the manual?

Power Electronics VS65 Series Specifications

General IconGeneral
BrandPower Electronics
ModelVS65 Series
CategoryController
LanguageEnglish

Related product manuals