Power Flame C6-GO-30 - User Manual

Default Icon
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
C MANUAL

Table of Contents

Other manuals for Power Flame C6-GO-30

Question and Answer IconNeed help?

Do you have a question about the Power Flame C6-GO-30 and is the answer not in the manual?

Summary

1. GENERAL PRODUCT INFORMATION

Principal of Operation

Explains the pressure atomization for oil and multiple orifice, venturi operation for gas.

COMPONENT INFORMATION-GENERAL

Figure 1 Burner Component Identification Typical for Model CR-GO with On-Off Fuel;Air Control Modes of Operation.*

Identifies components of a typical gas/oil burner with on-off fuel/air control.

INSTALLATION

GAS SUPPLY PIPING

Covers general guidelines and considerations for gas supply piping installation.

OIL SUPPLY PIPING

3. MECHANICAL OPERATION OF FUEL;AIR CONTROL MODES

Figure 17 Typical Gas Burner with On-Off Fuel;Air Control Mode...

Illustrates the mechanical operation of a gas burner with on-off fuel/air control.

Figure 18 Typical Gas Burner with Low-High-Off or Low-High-Low Fuel;Air Control Mode

Illustrates the mechanical operation of a gas burner with low-high-off/low-high-low control.

Figure 19 Typical Gas Burner with Full Modulation Fuel;Air Control Mode...

Illustrates the mechanical operation of a gas burner with full modulation control.

Figure 20 Typical Oil Burner with On-Off Fuel;Air Control Mode

Illustrates the mechanical operation of an oil burner with on-off fuel/air control.

Figure 21 Typical Oil Burner with Fixed Air Low Fire Start Fuel;Air Control Mode

Illustrates the mechanical operation of an oil burner with fixed air low fire start.

Figure 22 Typical Oil or Gas;Oil Burner with Reduced Air, Low Fire Start RALFS

Illustrates the mechanical operation of an oil/gas burner with reduced air, low fire start.

Figure 23 Typical Oil Burner with Low-High-Off or Low-High-Low Fuel;Air Control Mode Using Webster 22 R Oil Pump

Illustrates the mechanical operation of an oil burner with low-high-off/low-high-low control.

Figure 25 Typical Oil Burner with Full Modulation Fuel;Air Control (Model C-O)

Illustrates the mechanical operation of an oil burner with full modulation control.

4. GENERAL START UP PROCEDURES-ALL FUELS

All Fuels - General Start Up

Outlines general procedures and recommendations for burner start-up.

5. GAS START UP

Burner Start Up Sequence Instructions

Outlines step-by-step instructions for gas burner start-up sequences.

Burners Designed for Full Modulation Operation

Details specific start-up adjustments for burners designed for full modulation.

6. OIL START UP

Burner Start Up Sequence

Outlines step-by-step instructions for oil burner start-up sequences.

7. SERVICING AND COMPONENT ADJUSTMENTS

General Information on Internal Bypass Oil Nozzle Systems

Details internal bypass oil nozzle systems, their operation, and pressure ratings.

8. MAINTENANCE

Periodic Check List

Lists recommended periodic checks for burner components and settings.

9. BURNER START UP INFORMATION & TEST DATA

10. OWNER OPERATING INSTRUCTIONS

START UP

General preparation steps before starting the burner for all fuels.