7
CLAMP PERFORMANCE
ITEM INDICATION STANDARD DESCRIPTION
High Voltage
Protection
Red Light
Flashing
>16.7V(+3%)(45) Please check the voltage of Jump
Starter port when you ready to
used, High Voltage like > 16.7V may
cannot started. Tips:The Red lights
of battery clamp will keep flashing.
Low Voltage
Protection
Red Light
Flashing
<12.8V(±3%)(4S) Please check the voltage of Jump
Starter port when you ready to used,
High Voltage. Tips: The Red lights of
battery clamp will keeping flashing.
Startup 30S±2%
Start Current 600A±10% 0.1-0.3S 1000A
0.55 800A
25 600A
Reverse
Charging
Protection
Red and
Green Light
Flashing
Support If there is any reverse current, The
clamps will turn o the output
Automatically. Tips: The Red and
Green lights of battery clamp will
keeping flashing.
Short-Circuit
Protection
Red Light
Flashing
Support When the Two Clamps are
connected, The battery clamp will
be in a Short Circult Protection
Mode. Tips: The red lights of battery
clamp will keep flashing, the buzzer
will sound, no output and sparks.
Reverse
Polarity
Protection
Red Light
Flashing
Support When the Clamps are reverse
connected to the car battery,The
battery clamp will be in a Reverse
Polarity Protection Mode.
Tips: The Red lights of battery clamp
will keeping flashing,the buzzer will
sound, no output and sparks.
High
Temperature
Protection
Red Light
Flashing
Support Clamps will be cut o automatically
when operation temperature is too
high. Tips: Protection temperature:
80ºC ±5ºC
Working Status Green Light
On
Support The Jump Starter is ready to start
the car
Standby Support The Red and Green lights of battery
clamp will be keeping flashing when
ready to use.