VII. Fault Codes
E1 reverse connec (please correct)
E2
open circuit prot on ry not connected / or low
voltage
E3
overcurrent prot on (circuit has constant current
the machine may be damaged if there is an error)
E4
Load overcurrent /short circuit protec
(error 10S, turn on the
load
elimina g the error)
E5 overvoltage (ba ery damaged or high ry voltage)
E6 PV (solar) input overvoltage protec on (PV>135V)
E7
Over-temperature protec
, stop charging when heat sink
temperature90°C; resume when temperature60°C
E8 PV reverse conne on (please correct)
ery over and under voltage range
Capacity:12V/24V/36V/48V
low-voltage pr LCD
display:E2
<8/18/27/36V
Capacity:12V/24V/36V/48V
Over voltage protec on LCD
display:E5
>15/31/45/60V
Remark: Please eliminate the fault according to the error code. If the
machine s
does not respond the error is eliminated, it may be
damaged and need
-sales service.