EasyManua.ls Logo

PowMr POW-SunSmart 10KE - User Manual

Default Icon
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Questions and Answers

  • T
    Taylor Day Jr.Aug 15, 2025
    What to do if my PowMr POW-SunSmart 10KE Inverter shows 'Bypass over-load (software detection)'?
    • N
      Nancy ChangAug 15, 2025
      If your PowMr Inverter displays a 'Bypass over-load (software detection)' error, it means the bypass output power or current has been too high for too long. To resolve this, reduce the power being drawn by your connected devices and then restart the inverter. For further details, consult protection feature item 11.
  • M
    Michelle BrownAug 18, 2025
    What to do if PowMr POW-SunSmart 10KE Inverter says 'Battery not connected'?
    • K
      Katelyn WeaverAug 18, 2025
      If your PowMr Inverter indicates 'Battery not connected', verify the battery is properly connected. Also, check that the battery's circuit breaker is closed and that the BMS of the Li-ion battery can communicate correctly.
  • R
    Robert LopezAug 21, 2025
    Why does my PowMr POW-SunSmart 10KE Inverter show 'Battery over-voltage when charging'?
    • T
      Theresa CampbellAug 21, 2025
      If your PowMr Inverter shows a 'Battery over-voltage when charging' error, the battery voltage is too high. You should manually power off and restart the inverter. Check if the battery voltage exceeds the limit. If it does, discharge the battery until its voltage is below the over-voltage recovery point.
  • L
    Laurie MaddoxAug 25, 2025
    What to do if PowMr POW-SunSmart 10KE Inverter indicates 'Battery over-discharge'?
    • H
      Heather CampbellAug 26, 2025
      If your PowMr Inverter displays a 'Battery over-discharge' error, it signifies that the battery voltage is lower than the value set in parameter [12]. You can manually reset it by powering off and restarting the device. Alternatively, it will automatically reset once you charge the battery so that the battery voltage exceeds the value set in parameter [35].
  • V
    Victoria CarrollAug 28, 2025
    Why does my PowMr POW-SunSmart 10KE show 'Battery under-voltage'?
    • D
      Derek GreenAug 28, 2025
      If your PowMr Inverter shows a 'Battery under-voltage' error, the battery voltage is lower than the value set in parameter [14]. Charge the battery until its voltage is higher than the value set in that parameter.
  • C
    cheryldeanAug 31, 2025
    What causes 'Utility input phase fault' on my PowMr POW-SunSmart 10KE Inverter?
    • R
      Rebecca RobersonSep 1, 2025
      If your PowMr Inverter displays 'Utility input phase fault', it means the AC input phase doesn't match the AC output phase. Make sure the AC input phase is the same as the AC output phase. For example, if the output is in split-phase mode, the input must also be in split-phase.
  • B
    Billy WhiteSep 4, 2025
    How to fix a PowMr Inverter with 'Screen no display'?
    • J
      Jacqueline JacksonSep 4, 2025
      If your PowMr Inverter screen is not displaying anything, it could be due to no power input or the device being in sleep mode. Ensure the circuit breaker is closed and the rocker switch is ON. If it's in sleep mode, push any button on the panel to wake it up.
  • L
    Leslie JenkinsSep 7, 2025
    What should I do if my PowMr POW-SunSmart 10KE Inverter reports a 'Fan failure'?
    • J
      Jose ContrerasSep 7, 2025
      If your PowMr Inverter reports a 'Fan failure', the hardware has detected a fan issue for 3 seconds. Try manually toggling the fan after switching off the device to check if it's blocked by any foreign objects.
  • F
    fadamsSep 10, 2025
    What does 'AC Input relay short-circuit' mean on my PowMr POW-SunSmart 10KE Inverter?
    • W
      woodjenniferSep 12, 2025
      If your PowMr Inverter indicates an 'AC Input relay short-circuit', it suggests the relay for AC input is sticking. Manually power off and restart the device. If the fault persists after restarting, contact after-sales service for repair.

Summary

Important Safety Instructions

Installation

Select the Mount Location

Guidelines for choosing an appropriate installation site, considering environment and accessibility.

Mount the Inverter

Step-by-step instructions for physically mounting the inverter unit onto a wall securely.

Connection

Cable & Circuit Breaker Requirement

Specifies required cable diameters and circuit breaker ratings for PV, AC, and battery connections.

AC Input & Output Connection

Instructions for correctly connecting AC input and output wires according to terminal layout.

Battery Connection

Guidance on properly connecting the positive and negative battery cables to the inverter.

PV Connection

Instructions for connecting the positive and negative wires of PV strings to the inverter.

Operation

Setting

Detailed guide on navigating the setup menu and configuring various operational parameters.

Fault and Remedy

Fault Code

A comprehensive list of fault codes, their meanings, and impact on inverter operation.

Troubleshooting

Provides causality and remedies for common fault codes and operational issues.

Protection and Maintenance

PowMr POW-SunSmart 10KE Specifications

General IconGeneral
ModelPOW-SunSmart 10KE
TypeHybrid Inverter
Rated Power10 kW
Frequency50/60 Hz
Max. Input Current22A
Max. Charging Current100 A
Battery Voltage48 VDC
CoolingFan Cooling
Operating Temperature-10°C to 50°C
Input Voltage Range120-450V
Max. DC Input Voltage500V
Output Voltage230 VAC
CommunicationRS485, Wi-Fi
ProtectionOverload, Short Circuit, Over Temperature
Humidity5% to 95% (non-condensing)