18
13.5 - Miller Edge reexi Gard Connection
PREPARING PHOTOEYE
Reassemble the photoeye.
To align the photoeye assemble the hood on then reector.
Place the photocell directed at the reector and check the green light below the photocell lens (it will turn solid green when properly
aligned).
The red light at the top of the photocell will be o whenever the photocell is aligned and unobstructed, and is on whenever something
is between the photocell and the reector.
TRIFLEX PROGRAM (UL 325 2018)
To enable the second photocell:
Put the dipswitch # 8 in On position, press and release the "+" button, return the dipswitch to OFF position.
To disable the second photocell:
Put the dipswitch # 8 in On position, press and release the "-" button, return the dipswitch to OFF position.