1.1 Controller Specifications

Details the electrical and operational specifications of the CD30/35 controller.

1.2 Application

Lists the PPM equipment models that the CD30/35 controller has been tested with.

1.3 Safety Considerations

Provides essential safety instructions and warnings for the product's correct application.

Wiring

2.1 Power

Explains incoming plant power and outgoing power to the coil connections.

2.2 Feedback Sensor

Details the wiring for DMT/Mag II sensors and PPM accelerometers.

2.3 System control wiring

Covers wiring for unit enablement, external set points, status relay, and second set points.

2.4 Recommended Method for Installing a Frequency Controller

Recommends methods and components for installing a frequency controller.

CD30;35 Important Menu Settings

3.1 Basic Display Navigation

Explains how to navigate the controller's display and settings menus.

3.2 C210, C143, C127, C117 (Save & Hide Settings)

Describes menu codes for hiding functions/service menus and saving/restoring settings.

3.3 C038 Function Settings

Details the various function settings available within menu C038.

3.4 C040 Service Settings

Outlines the service settings accessible within menu C040.

Step by Step Setup Procedure

4.1 Wire CD30;35

Guides on connecting incoming power, outgoing power, and feedback sensors.

4.2 Initial CD30;35 Menu Settings for PPM Equipment

Provides initial menu parameter settings for PPM equipment.

4.3 Set Sensor Position

Explains how to adjust the sensor gap for proper operation.

4.4 Run Automatic Frequency Search (AFS)

Details the process of performing an AFS to find the conveyor's resonant frequency.

4.5 Set Operating Characteristics (A & P)

Guides on setting amplitude (A) and power (P) for optimal feeder performance.

4.6 Save User Settings & Hide Menus

Instructions on saving user settings and hiding configuration menus.

Main Fault Messages

5 FAULT MESSAGES

Lists and explains various error messages displayed by the controller.

Troubleshooting

6 TROUBLESHOOTING

Provides solutions for common feeder and controller operational problems.

Special Applications

7.1 Master;Slave Control

Explains how to set up master/slave control for larger feeders.

7.2 Single Controller for Multiple Magnet Coils

Describes using a single controller for multiple magnet coils in parallel.

PPM CD30 Specifications

General IconGeneral
Contact Current Rating10 A
Coil Voltage3 VDC, 5 VDC, 6 VDC, 9 VDC, 12 VDC, 24 VDC, 48 VDC
Release Time5 ms
Mechanical Life10, 000, 000 Operations
Contact Rating10A @ 250V AC, 10A @ 30V DC
Electrical Life100, 000 operations
Insulation Resistance1000MΩ
Dielectric Strength1500V AC