Page 13
Procedure 4.3 - Display Diagnostics
Note:
This section is applicable only for units with software versions 1.02 (both lower and upper
software) only. Software version lower than 1.02 to not support display diagnostics.
1. Since it is necessary to depress a key on the display as the unit is being powered up, it will
be necessary to have an assistant power the unit up while you press the display key (unless
you have very long arms).
2. Press and hold the RESET key as the on/off switch is set in the on position. Do not release
the RESET key.
3. Four eights will be displayed. Check to ensure that all of the display segments are
illuminated.
4. While continuing to depress the RESET key, press each of the remaining keys one at a
time. As each key is depressed a corresponding L.E.D. segment will go out, indicated that
the key being pressed is functioning normally.
5. While continuing to depress the RESET key, depress both “” keys. When both “” keys are
depressed, release the RESET key, while continuing to depress both “” keys. The upper
software version will be displayed.
6. While continuing to depress both “” keys, press both “”. When both “” are depressed,
release both “”, the lower software version will be displayed.
7. Release both “”to exit the display diagnostics.