8. Slide the replacement ramp onto the lift motor yoke and hand. Hand start the two lower
ramp mounting bolts removed in step 5. Fasten the upper end of the ramp to the lift motor
yoke with the hardware removed in step 6. Torque the two lower ramp bolts to 480 inch
pounds (40 foot pounds).
Diagram 7.14 - Upper Ramp Mounting (Viewed from under the ramp)
9. Replace both stairarms per Procedure 7.17.
10. Replace the left and right cover sections per Procedure 7.1.
Yoke
Mounting Bolt