Precor AMT 885 - Unit reboots of its own volition

Precor AMT 885
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 121
3 Check yellow/black cable in console for damage. Ensure the cable is
inserted fully onto the pins. If not inserted properly, insert. If
cable is damaged, console must be replaced; this is not a
replaceable part.
4 If machine controls have failed, the entire console will need to be
replaced. This is not a replaceable part.
Machine Controls Incorrect Response
Description
Machine controls do not respond properly to input speed up makes
speed go down, incline up makes incline go down, etc.
Possible Causes
1 Bounce-back If the user if flipping the machine controls with a lot
of force, the control could rebound with enough force to cause it to
bounce in the other direction, causing the machine to think the user
is actually pressing it in that direction.
2 Cable from machine controls to upper board is damaged or not
inserted properly.
3 Machine controls have failed
Possible Remedies
1 Verify the user is not using excessive force on the controls. Test
to make sure they are operating properly when appropriate force is
used. Educate customer on proper use of equipment.
2
Test controls in Systems Tests. SeeP80 System Tests (on page 63).
Check yellow/black cable in console for damage. Ensure the cable
is
inserted fully onto the pins. If not inserted properly, insert.
If
cable is damaged, console must be replaced; this is not a
replaceable part.