Page 278
20 Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
21 Select the QUICKSTART program and adjust the resistance key until
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.
Figure 216: Generator
22 The drive input belt tension should read approximately 135 ±5 lbs
and the generator belt tension should read approximately 85 ±5 lbs.
See Drive Belt Gauge Instructions (on page 142)
23 Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
24 Replace the covers as per procedure, Cover Replacement (on page 152).
Replacing the Generator
Procedure
1 Remove the covers as per procedure, Cover Replacement (on page 152).
2 Remove the lower PCA cover as per procedure, Lower PCA Cover (see
"Removing the Lower PCA Cover" on page 268).