Page 41
Section Four
P30 Troubleshooting
In This Section
Troubleshooting the Keypad and Upper PCA........... 41
Troubleshooting the Handheld Heart Rate............ 44
P30 AMT '11 - Upper Display does not Illuminate.... 48
Troubleshooting the Keypad and Upper PCA
Procedure
Note: The white or yellow wire on the cables shown below denotes pin 1.
When these cables are inserted into their connectors, the white or yellow wire
must align with the pin 1 designation on the PCA.
1 Set the treadmill’s on/off switch in the off position (Treadmill
only). Access the upper electronics and machine controls per
Replacing the Upper PCA (on page 28), steps 1 through 12. Place the console
on the maintenance mounting hook and reconnect all cables.
2 If the message STUCK KEY is displayed when the unit is turned on for
treadmill’s or pedaling on the RBK, UBK, AMT, and EFX, skip to step
23.
3 If a key does not function, skip to step 18.
4 If the display does not illuminate, continue with step 5.