Page 3
Operational Parameters
Do not use with water that is microbiologically unsafe or of unknown quality, without
adequate disinfection before or after the system. Installation needs to comply with state and
local plumbing regulations.
Maximum Minimum
Operating Temperature: 100° F (37.8° C) 40° F (4.4°C)
Operating Pressure: 100 psi (7.03 kg/cm²) 20 psi (1.41 kg/cm²)
pH Parameters 10 5
Flow Rate 0.5 gpm @ 60 psi
Contents of CT-1 System
1 CT-1 Housing with Filter Inside
1 Faucet Diverter with white tube
1 Diverter adapter kit
1 Manual
If any of the items are missing please contact
Premier prior to installing.
Tools Recommended
For Installation
A pair of pliers may be required
Installation
Step A: Remove the faucet aerator by turning it clockwise, (as shown in Figure A).
Figure A: Removing Faucet Aerator