Page 15
Annual Sanitization
NOTICE
'RQRWFKDQJH\RXUSRVWFDUERQ¿OWHUXQWLOWKHVDQLWL]DWLRQKDVEHHQFRPSOHWHG
7KHSUH¿OWHUVDQGPHPEUDQHFDQEHFKDQJHGEHIRUHWKHVDQLWL]DWLRQ
Step 1: Turn off the water supply to your RO system at the adapt-a-
valve and open the RO faucet to drain the storage tank.
NOTICE
If you have connected your RO system to a refrigerator/
ice maker, make sure the connection has been turned
RII'RQRWUHRSHQWKHFRQQHFWLRQXQWLOWKHVDQLWL]DWLRQ
process is complete.
6WHS /RFDWHWKHWXEHWKDWUXQVEHWZHHQ\RXU¿OWHUPRGXOHDQGWKH
storage tank and disconnect at both ends.
Step 3: Drain any remaining water in the tube
Step 4: Hold both ends of the tube together with the ends pointed
DZD\IURP\RXU IDFH 8VLQJDGRVLQJV\ULQJH VHH ¿JXUH
slowly insert 1 teaspoon (5 mL) of common household bleach
into the tube.
WARNING
!
Do not use needle syringe
DANGER
!
,)%/($&+*(76,1(<(6+ROGH\HRSHQDQGULQVH
slowly and gently with water for 15 - 20 minutes.
Remove contact lenses if present, after the first 5
minutes, then continue rinsing eye. Call a poison
control center or doctor for treatment advice.
6WHS :KLOHFRYHULQJRQHHQGRIWKHWXEHZLWK\RXU¿QJHULQVHUWWKH
RWKHULQWRWKHWDQN7KHQLQVHUWWKHRSHQHQGLQWRWKH¿OWHU
module.
6WHS 7XUQWKHLQFRPLQJZDWHUEDFNRQDQGOHWWKHV\VWHP¿OOIRU
approximately 10 minutes
Step 7: Turn off the incoming water and let the system sit for 1 minute.
Step 8: Drain the system completely and then follow the startup
SURFHGXUH¿OOLQJWKHQGUDLQLQJWZRIXOOWDQNVRIZDWHU
6WHS 5HSODFHWKHSRVWFDUERQ¿OWHURQFHFRPSOHWH
POINT HOSE
ENDS AWAY
FROM FACE
DOSING SYRINGE
WITH NO NEEDLE