Watts Premier
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
RO-Pure
6\VWHPFRQIRUPVWR16)6WDQGDUGIRUVSHFL¿FFODLPV
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description Change time Frame
6HGLPHQW3UH¿OWHU  0RQWKV
&DUERQ3UH¿OWHU  0RQWKV
3RVW&DUERQ¿OWHU  0RQWKV
*3'520HPEUDQH  WR\HDUV
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
HQWHULQJWKHV\VWHPZDVUHGXFHGWRDFRQFHQWUDWLRQOHVVWKDQRUHTXDOWRWKHSHUPLVVLEOHOLPLWIRUZDWHUOHDYLQJWKHV\VWHPDVVSHFL¿HGLQ16)$16,7KLV
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
FKORULQHLVQRWVXI¿FLHQWWRHQVXUHFRPSOHWHFRQYHUVLRQRIWULYDOHQWDUVHQLFWRSHQWDYDOHQWDUVHQLF3OHDVHVHHWKH$UVHQLF)DFWVVHFWLRQRIWKH3HUIRUPDQFH'DWD
Sheet for further information.
$YJ,Q $YJ(II 5HGXFWLRQ S+ 3UHVVXUH 0D[(II ,QIFKDOOHQJH 0D[$OORZDEOH
(mg/L) (mg/L) mg/L concentration concentration
mg/L mg/L
Arsenic (Pentavalent) .310 0.001 99.6% 7.24 50psi 0.002 0.30±10% 0.010 mg/L
Barium Reduction 9.2 0.08 99.0% 7.64 50psi 0.12 10.0±10% 2.0
Cadmium Reduction 0.031 0.0004 98.0% 7.49 50psi 0.0008 0.03±10% 0005
Chromium (Hexavalent) 0.30 0.002 99.0% 7.24 50psi 0.004 0.03±10% 0.1
Chromium (Trivalent) 0.30 0.001 99.0% 7.64 50psi 0.002 0.03±10% 0.1
Copper Reduction 3.2 0.02 99.0% 7.40 50psi 0.04 3.0±10% 1.3
&\VWV PO PO   SVL  PLQLPXPP/ 1$
Fluoride Reduction 8.7 0.19 97.0% 7.24 50psi 0.3 8.0±10% 1.5
Lead Reduction 0.15 0.002 98.8% 7.39 50psi 0.005 0.15±10% 0.0107
Perchlorate 130 2.8 97.9%
Radium 226/228 25pCi/L 5pCi/L 80.0% 7.24 50psi 5pCi/L 25pCiL±10% 5pCiL
Selenium 94.85 <0.2 97.0% 7.24 50psi <0.2 0.10±10% 0.05
TDS 770 35 95.0% 7.28 50psi 26.0 750±40mg/L 187
Turbidity 11.3 0.1 99.0% 7.43 50psi 0-1 11±1mg/L 0.5NTU
5HFRYHU\ 'DLO\3URGXFWLRQ5DWH*3' (I¿FLHQF\
Depending on water chemistry, water temperature, and water pressure Premiers R.O. Systems production and performance will vary.
(I¿FLHQF\UDWLQJPHDQVWKHSHUFHQWDJHRIWKHLQÀXHQWZDWHUWRWKHV\VWHPWKDWLVDYDLODEOHWRWKHXVHUDVUHYHUVHRVPRVLVWUHDWHGZDWHUXQGHU
RSHUDWLQJFRQGLWLRQVWKDWDSSUR[LPDWHW\SLFDOGDLO\XVDJH5HFRYHU\UDWLQJPHDQVWKHSHUFHQWDJHRIWKHLQÀXHQWZDWHUWRWKHPHPEUDQHSRUWLRQ
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (480) 675-7995 Fax: (623) 866-5666 www.PremierH2o.com
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
LVPLFURELRORJLFDOO\XQVDIHRUXQNQRZQTXDOLW\ZLWKRXWDGHTXDWHGLVLQIHFWLRQEHIRUHDQGDIWHUWKHV\VWHP6\VWHPVFHUWL¿HGIRUF\VWUHGXFWLRQPD\EHXVHGRQ
GLVLQIHFWHGZDWHUWKDWPD\FRQWDLQ¿OWHUDEOHF\VWV
7KLVV\VWHPLVDFFHSWDEOHIRUWUHDWPHQWRILQÀXHQWFRQFHQWUDWLRQVRIQRPRUHWKDQPJ/QLWUDWHDQGPJ/QLWULWHLQFRPELQDWLRQPHDVXUHGDV1DQG
LVFHUWL¿HGIRUQLWULWHQLWUDWHUHGXFWLRQRQO\IRUZDWHUVXSSOLHVZLWKDSUHVVXUHRIN3DSVLJRUJUHDWHU,I\RXUZDWHUVXSSO\LVXQGHUSVL3UHPLHU
recommends the use of a RO booster pump for proper operation.
3. Operating Temperature: Maximum: 100°F (40.5°C) Minimum: 40° (4.4°)
4. Operating Water Pressure: Maximum: 85 psi (6.0kg/cm2) Minimum: 40 psi (2.8kg/cm2)
5. pH 2 to 11
6. Maximum Iron present in incoming water supply must be less than 0.2 ppm.
7. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
8. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
TECHNICAL & WARRANTY INFORMATION