Page 13
4
3
6 Month System Maintenance
Step 3
Let system sit for one minute after the tank is empty to let the system depressurize before
attempting to remove fi lter housings.
Items needed:
Stage 1 - Sediment Filter (part #: 104017)
Stage 2 & 3 - Carbon Block Filter (part #: 101009-White End Caps)
Open the RO Faucet and allow water to drain from the tank until it is completely empty.
Step 2
Note:
Water may be saved in a container for drinking or to rinse system parts.
For more leverage you may leave the RO module attached to wall of
cabinet. If you are unable to access the module while it is mounted,
remove it prior to changing fi lters. Starting with the closest housing
(Stage 1), remove it by turning it clockwise (left), empty water, then
discard fi lter. Continue on to the 2
nd
housing (Stage 2) and 3
rd
housing
(Stage 3).
Step 4
Clean the fi lter housings (bowls) with a mild soap solution and rinse
with water. Check O-rings and lubricate with water soluble lubricant.
KY Jelly® or other water based lubricants may be used. Petroleum
based lubricants (such as Vaseline®) must not be used.
Step 5
Before re-installing the fi lter bowls back on to the system, check
O-rings to make sure they are still in place.
Caution:
Insert the new sediment fi lter (cloth like appearance) into the 1st fi lter
housing which is the one closest to the side with tubing connections
and re-install housing.
Step 6
Insert the new Carbon Block fi lter (White End Caps) into the second
and third stage housing and re-install housings.
Step 7
Step 8
Turn water on to the unit at the adapt-a-valve.
Open the RO faucet and leave it open until water begins to trickle out
(it will come out slowly).
Step 10
Step 9
Close the RO faucet allowing the storage tank to fi ll with water. It
may take 3 to 6 hours to fi ll the tank completely depending on the
production capability of the membrane, local water temperature and
water pressure.
*Order fi lters by calling 1-800-752-5582 or buy online at www.premierh2o.com.
MAINTENANCE & TROUBLESHOOTING
MAINTENANCE & TROUBLESHOOTING
Step 1
Note:
The fi lter wrench pictured (Part # 164003) may be purchased from Pre-
mier to aid with twisting off fi lter housings (not required).
Turn off the incoming water supply to the RO at the feed water valve.
(Follow the green tube away from the RO system to fi nd the valve.)
OFF