EasyManua.ls Logo

Premier WP-5 - Product Technical and Warranty Information; Performance Data and Technical Specifications

Premier WP-5
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 18
TECHNICAL & WARRANTY INFORMATION
TECHNICAL & WARRANTY INFORMATION
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description Change time Frame
Sediment Pre- lter: #104017 6 Months
Carbon Pre- lter: #101009 6 Months
Final Carbon lter #100017 12 Months
R.O. Membrane: #110009 2 to 5 years
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as speci ed in
NSF/ANSI 58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate)
at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to
be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to
contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not suf cient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
Avg. In. Avg. Eff. % Reduction pH Pressure Max Eff. Inf. challenge Max Allowable
concentration concentration
mg/L mg/L
Arsenic (Pentavalent) 334.615 ug/L 5.0385 ug/L 98.4% 50psi 19 ug/L 0.30±10% 0.010 mg/L
Barium Reduction 10.2 mg/L 0.207 mg/L 97.9% 7.24 50psi 0.3 mg/L 10.0±10% 2.0
Cadmium Reduction 0.036 mg/L 0.0005 mg/L 98.6% 7.49 50psi 0.0007 0.03±10% 0005
Chromium (Hexavalent) 0.15 mg/L 0.013 mg/L 91.3% 7.24 50psi 0.03 0.3±10% 0.1
Chromium (Trivalent) 0.17 mg/L .01 mg/L 94.1% 7.24 50psi 0.01 0.3±10% 0.1
Copper Reduction 3.1 mg/L 0.03 mg/L 99.0% 7.64 50psi 0.04 3.0±10% 1.3
Cysts 222,077#/ml 10 #/ml 99.99% 58 minimum 50,000/mL
Fluoride Reduction 8.0 mg/L 0.5 mg/L 93.9% 7.49 50psi 0.7 8.0±10% 1.5
Lead Reduction 0.15 mg/L 0.002 mg/L 98.6% 7.49 50psi 0.003 0.15±10% 0.010
Perchlorate 0.10 mg/L 0.003 mg/L 96.5% 7.39 50 psi 0.005 0.10±10% 0.006
Radium 226/228 25pCi/L 5pCi/L 80.0% 7.24 50psi 5pCi/L 25pCiL±10% 5pCiL
Selenium 0.10 0.008 92.0% 50psi 0.011 0.10±10% 0.05
TDS 765 23 mg/L 96.8% 7.84 50 psi 33 mg/L 750±40mg/L 187
Turbidity 10.2 mg/L 0.26 mg/L 97.5% 0.83 11±1 NTU 0.5 NTU
Recovery - 16.23% Daily Production Rate - 9.56 GPD Ef ciency - 9.58%
Depending on water chemistry, water temperature, and water pressure Premier’s R.O. Systems production and performance will vary.
Ef ciency rating means the percentage of the in uent water to the system that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage. Recovery rating means the percentage of the in uent water to the membrane portion of the system that is
available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed. There is
an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
Phone: (480) 675-7995 Fax: (623) 866-5666 Email: wpmail@Premier.com
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use
with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certi ed for cyst
reduction may be used on disinfected water that may contain lterable cysts.
2. Operating Temperature: Maximum: 100°F (40.5°C) Minimum: 40° (4.4°)
3. Operating Water Pressure: Maximum: 85 psi (7.0kg/cm2) Minimum: 40 psi (2.8kg/cm2)
4. pH 2 to 11
5. No iron present in incoming feed water supply.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Premier Inc.
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
(480) 675-7995 wpmail@Premier.com