First set the replenishment water level of the nutrient pool (less than or equal to this water
level, the system will automatically sta the action of replenishing water), high water level (more
than this water level, the nutrient pool may ovelow, and the system will alarm), low water level
(less than or equal to this water level, trigger to stop irrigation , stop feilizer distribution, stop
mixing), target water level.
The user sets the target water level according to the water demand of the crops and the
frequency of feilizer distribution.
The Manual function is convenient for users to manually add water to the target water level.
When using Aqua-Pro for the rst time, rst click Manual and then click ON to add water manu-
ally. After reaching the target water level, the system will automatically turn to OFF. You can also
manually click OFF to turn o water addition.
In the state of automatic water replenishment, set the alarm time.If the system fails to reach the
target water level within the set time, the system will alarm and continue to replenish water until
the target water level is reached.
Note: When the water supply time and timeout alarm are set to zero, under the condition of irriga-
tion priority, irrigation will not stop during the process of system triggering water replenishment,
unless the irrigation is suspended due to low water level or other conditions, applicable to irrigation
Non-stop NFT application scenes.
NUTRIENT
Click [NUTRIENT] to enter the feilizer distribution settings:
A
Monitor mode: In the ON state, the peristaltic pump
does not operate at this time, and the system
monitors the EC, water temperature, and pH value
of the nutrient pool; In the OFF state, the automatic
formula setting will be executed.
Click Monitor to make it in the on state. At this time,
the peristaltic pump does not work, and the system
will monitor the water temperature, EC and pH
value of the nutrient pool.
Daily regular feilizer supplement plan: the purpose
is to replenish the feilizer in the nutrient bucket to
reach the target EC and PH value, even if the EC and
pH peristaltic pump may not meet the conditions for
restaing at this time. EC and pH can be set
separately.
Daily regular feilizer supplement plan: the purpose
is to replenish the feilizer in the nutrient bucket to
reach the target EC and PH value, even if the EC and
pH peristaltic pump may not meet the conditions for
restaing at this time. EC and pH can be set
separately.
A.
B.
Click Setting and recipe to enter
the recipe selection setting
inteace.
C.
B
C
11