Some modules can peorm seconda settings on the type of sub-pos.
Supply (pump or valve)
(Fresh water)
Irrigation Pump
(IRR Pump)
Irrigation Master Valve
(IRR Main Valve)
Mixing Valve
Associated with the water level sensor, the water replenishment will be
staed when the water level is less than or equal to the replenishment water
level, and the replenishment will be stopped when the target water level is
reached.
When peorming the mixing function, it will act synchronously with the
irrigation pump.
Nutrient pool
independent mixing
(Mix-Reseior)
The separate mixing device can car out self-timed mixing of the feilizer
liquid in the nutrient pool or synchronous mixing when the peristaltic pump is
distributing feilizers, and it also has the function of manual mixing.
Stock solution bucket mixing
(Mix- Bottle)
The separate mixing device can automatically and regularly mix the stock
solution, and also has the function of manual stirring.
Irrigation sub-valve
(IRR Sub Valve)
Multiple sub-valves realize the irrigation function in turn.
Associated with the water level sensor, there are feilizer distribution priority
mode and irrigation priority mode, and the default is irrigation priority.
The irrigation pump combined with the irrigation main valve and the mixing
valve can also realize the mixing function under the condition of self-circula-
tion. When the irrigation pump executes the irrigation command, the mixing
valve is closed, the irrigation pump and the irrigation main valve are opened
at the same time, and when the irrigation pump peorms the mixing function,
Close the main irrigation valve, and the irrigation pump and mixing valve are
turned on simultaneously.
Synchronize with the irrigation pump when peorming the irrigation function.
Node output control type Note