Click [HISTORIC DATA] to enter the historical alarm data inteace:
Alarm type classication:
Resta after power failure: The
system runs related programs
according to the current clock and
sends an alarm to the user's mobile
phone. The user can manually turn
on or o functions such as water
replenishment, feilizer distribu-
tion, mixing, and irrigation.
Oine alarm and action: Environ-
mental control four-in-one sensor:
oine alarm, temperature, humidi-
ty, carbon dioxide stop working,
resta after going online;
Water level sensor: oine alarm;
EC probe: oine alarm, stop
feilizer distribution, resta after
online
EC\Ph control module: Oine
alarm, stop feilizer distribution,
resta after online
Equipment control module:
Oine alarm, the control
equipment stops working, and
restas after going online.
HISTORIC DATA
High Water Level Alarm: Alarm when water level is high.
Low Water Level Alarm: Alarm when water level is low.
The target EC value timeout: In the specied time of feilizer distribution
(the maximum number of continuous operation parameters of liquid
addition exceeds the preset requirements), EC cannot reach the target value.
The target pH value timeout: The pH cannot reach the target value within
the specied time of feilizer distribution the maximum number of
continuous running times of liquid addition exceeds the preset requirement).
pH High Alarm: Alarm when pH is high.
pH Low Alarm: Alarm when pH is low.
EC High Alarm: Alarm when EC is high.
EC Low Alarm: Alarm when EC is low.
High temperature alarm(WATER): Alarm when water temperature is high.
Low temperature alarm(WATER): Alarm when water temperature is low.
Peristaltic tube replacement: Alarm when the peristaltic pump hose
needs to be replaced.
High temperature alarm (AIR): Alarm when ambient temperature is high.
High humidity alarm: Alarm when humidity is high
Low humidity alarm: Alarm when humidity is low;
High carbon dioxide alarm: Alarm when carbon dioxide concentration is high.
Sensor needs maintenance: Alarm when the sensor needs to be replaced.
BLS-WL Sensor is not connected.
BLS-4 Sensor is not connected.
EC Sensor is not connected.
pH Sensor is not connected.
BLS-MM Sensor is not connected.
BLS-WL/WD Sensor is not connected.
BCB-12/BDC-4 Device is not connected.
BSS-4/BCS-PU1 Device is not connected.
LDA-1/LDA-SPE Device is not connected.
BTS-AR Device is not connected.
Soil Low Alarm: Alarm when soil moisture is low.
Smoke Detector Alarm.
Water Leakage Alarm.