Click [HISTORIC DATA] to enter the historical alarm data inteace:
Alarm type classication:
Resta after power failure: The
system runs related programs
according to the current clock and
sends an alarm to the user's mobile
phone. The user can manually turn
on or o functions such as water
replenishment, feilizer distribu-
tion, mixing, and irrigation.
Oine alarm and action: Environ-
mental control four-in-one sensor:
oine alarm, temperature, humidi-
ty, carbon dioxide stop working,
resta after going online;
Water level sensor: oine alarm;
EC probe: oine alarm, stop
feilizer distribution, resta after
online
EC\Ph control module: Oine
alarm, stop feilizer distribution,
resta after online
Equipment control module:
Oine alarm, the control
equipment stops working, and
restas after going online.
HISTORIC DATA
High Water Level Alarm: Alarm when water level is high.
Low Water Level Alarm: Alarm when water level is low.
The target EC value timeout: In the specied time of feilizer distribution
(the maximum number of continuous operation parameters of liquid
addition exceeds the preset requirements), EC cannot reach the target value.
The target pH value timeout: The pH cannot reach the target value within
the specied time of feilizer distribution the maximum number of
continuous running times of liquid addition exceeds the preset requirement).
pH High Alarm: Alarm when pH is high.
pH Low Alarm: Alarm when pH is low.
EC High Alarm: Alarm when EC is high.
EC Low Alarm: Alarm when EC is low.
High temperature alarm(WATER): Alarm when water temperature is high.
Low temperature alarm(WATER): Alarm when water temperature is low.
Peristaltic tube replacement: Alarm when the peristaltic pump hose
needs to be replaced.
High temperature alarm (AIR): Alarm when ambient temperature is high.
High humidity alarm: Alarm when humidity is high
Low humidity alarm: Alarm when humidity is low;
High carbon dioxide alarm: Alarm when carbon dioxide concentration is high.
Sensor needs maintenance: Alarm when the sensor needs to be replaced.
BLS-WL Sensor is not connected.
BLS-4 Sensor is not connected.
EC Sensor is not connected.
pH Sensor is not connected.
BLS-MM Sensor is not connected.
BLS-WL/WD Sensor is not connected.
BCB-12/BDC-4 Device is not connected.
BSS-4/BCS-PU1 Device is not connected.
LDA-1/LDA-SPE Device is not connected.
BTS-AR Device is not connected.
Soil Low Alarm: Alarm when soil moisture is low.
Smoke Detector Alarm.
Water Leakage Alarm.
23