Peristaltic pump channel feilizer absorption error manual correction function (due to various
reasons such as the length of the external silicone tube of the peristaltic pump, the feilizer absorp-
tion amount of each channel is inconsistent, etc.)
Select the currently used
peristaltic pump rate/minute and
test working time. Use a measuring
cup (purchase separately, need to
be larger than the required calibra-
tion capacity) to measure it.
Select and current peristaltic
pump rate (rate/min) and single
test working time. Use a standard
measuring cup (purchase
separately, need to be larger than
the required calibration capacity)
to calibrate a single test to obtain
the nutrient solution. Fill in the read
value into the corresponding
calibration data area and save it to
automatically calculate the calibra-
tion ratio of the peristaltic pump.
Peristaltic pump error manual correction function
Network setting inteace: set the device IP and seer related information after the device is
connected.